Definition |
In this action, a cable is split, resulting in 1 new cable and a new sleeve, which are placed between the two (old and new) cables.
|
Split cable segments |
If the original cable is subdivided into several cable segments, these are allocated to the two cables, where 2 options are possible: •The location of the sleeve is identical to the end location of a cable segment. •The location of the sleeve is not identical to the end location of a cable segment.
|
Left / Right |
This information in the workflow “Split cable, insert sleeve” indicates where the new cable is located in the newly created structure.
|
Sleeve |
The new created sleeve must have at least the dimension of the cable. An existing sleeve without cross-connections can also be selected.
|
New cable |
The new cable receives the same component type as the original cable.
|
Cross-connections |
The original cable is connected to the sleeve 1:1 (e.g. left) and the new cable is connected 1:1 with the sleeve (e.g. right). Cross-connections remain unchanged at the cable ends; however, they belong to different cables as new connections.
|
Options |
There are several options for the interconnection of the internal connection. •1:1 patched through •Open •Only connect used or named paths |