Equipment

Just like cables, components of the category „Duct/Route“have 2 locations. Hence in components of this category, only “Cables” or in turn “Duct/Route” (subordinate Duct) can be equipped.

 

End locations

The end locations of the “Duct/Route” are designated as follows:

A location

Z location

These 2 locations must be defined on creating a Duct; they may, however, be identical.

 

End components

In addition to the end locations of the “Duct/Trench”, 2 final components can be defined for the Duct:

A component

Z component

The following additional characteristics can be defined on the Duct/Route:

 

Characteristic

Type

Description

Effective length

Number

Effective length of the Duct in metres.

GIS length

Number

Read from MapXtreme 2-D length of Duct/Route in the card

Inside size

Text (20)

Inherited from the component type, can also be modified on the component.

Tag

Text (50)

Inherited from the component type, can also be modified on the component.

Colour

Text (6)

Name of colour.

 

Cascading

In order to document pipe systems, it is possible to equip subordinate ducts in a duct.

 Example:CM-MAN~3_img214

 

A cable begins in Location A, ends in Location B. Between A and C, it lies in the duct Sub A. The shaft C lies in C. This is where the duct Sub A ends. The cable is fed-through through the shaft.  The duct B ends also in shaft C. Between C and B, the cable is drawn through the duct B that ends in Location B.